Welcome to ATLab LLC
The AT-1206 intelligent dissolution system is a high-performance 12-cup and 12-rod dissolution testing device designed and manufactured in accordance with the requirements of the 2020 edition of the Chinese Pharmacopoeia, the US Pharmacopoeia, and the Guiding Principles for Mechanical Validation of Drug Dissolution Meters.
- Comply with the requirements of the Chinese Pharmacopoeia, the American Pharmacopoeia, and the Guiding Principles for Mechanical Validation of Drug Dissolution Meters.
- Can accommodate 12 dissolution cups and 12 rods.
The driving head of the dissolution instrument adopts an intelligent automatic lifting method, and the imported electric lifting column ensures the accurate and reliable lifting of the dissolution instrument head. It ensures the reproducibility of key parameters such as the setting height and center position of the mixing shaft in experimental conditions.
Use a non-resident high-precision temperature probe to monitor the temperature of the dissolved medium at a predetermined time point and configure an integrated
sampling needle to ensure that the sampling position remains unchanged.
Adopting imported stepper motors to control the speed, ensuring accurate, stable and reliable speed.
Color touch screen with graphical display, easy and intuitive operation.
Byusing a large-sized touch screen, it is convenient to track user permission
settings and ensure that only allowed users can operate the instrument. It
fully complies with regulatory requirements such as USP/FDA.
260-AT Mechanical Verification
The 260-AT mechanical verification system is composed of various mathematical detections to bring higher analytical accuracy and efficiency to customers. At the same time, users can freely increase the authentication frequency to achieve higher integrity.
Tools and instruments: All tools and instruments are digitally displayed and have passed third-party metrological verification, with measurement reports attached.
Data transmission: Bluetooth or 232 data cable.
Data collection: All data collection requires computer version software to automatically collect, save, and display in real-time. The data collection frequency requires collecting 8 data per second.
Software function: Built in CFDA (2016 No. 78), FDA
(DPA-LOP.002), USP Toolkit (version 2.0), ASTM (E2503-07) standard parameters, automatically determining whether the experiment has passed the standard requirements, and generating a PDF report output.Universality: Suitable for all models of SOTAX, Hanson, and
Agilent.